    Cell Configuration: 4S4P

    Chemistry: LiFePO4

    Current

    Ah Capacity: 120Ah

    Max Continuous Discharge Amps: 150A

    Max Charge Current Amps: 100A

    Max Discharge Peak Current Amps: 800A @ 10s

    Series | Parallel: Max (4) in Series, Max (16) in Parallel

    Voltage

    Voltage: 12.8V

    Max Charge Voltage: 15.4V

    Operating Voltage Range: 10.0 - 15.4V

    Temperature

    Charge Temp Range: -20°C (-4°F) / 55°C (131°F) (with heating)

    Discharge Temp Range: -20°C (-4°F) / 60°C (140°F)

    Storage Temp: 0°C (32°F) / 35°C (95°F)

    Weights & Dimensions

    Weight: 29.7 lbs

    Dimensions

    Length: 12.25 (inches)

    Width: 6.75 (inches)

    Height: 9 (inches)

    Additional Information

    Compatible with the following chargers: Epoch, Noco Gen Pro, Dual Pro PS/ Auto, Minnkota Precision, Pro Mariner/Pro Tournament Elite, Stealth, Troll Bridge DC, Power Pole

    Magnuson-Moss Warranty Act: A vehicle manufacturer cannot legally void the warranty on a vehicle due to an aftermarket part unless they can prove that the aftermarket part caused or contributed to the failure in the vehicle (per the Magnuson Moss Warranty Act (15 U.S.C. 2302(C)). Epoch Batteries have proprietary software embedded in the Battery Management Systems that make them 100% compatible with Mercury 250 hp motors and other leading brands.

    Certifications:

    UL1973, RoHS, CE

    Recommended Charging Settings

    • To properly charge your Epoch Batteries, you will want to verify that any charging component in your system is capable of being programmed for the following specifications. Charging components can include, but are not limited to converters, inverter chargers, solar charge controllers, DC to DC chargers, etc.
    • Bulk/Absorption: 14.2V – 14.6V
    • Absorption Time: Two batteries in parallel connections require 30 minutes 200Ah
    • Float: 13.4V – 13.8V
    • Equalization: 14.4V/ Disabled
    • Temperature Compensation: 0/Disabled
    • Charge Rate: 50% of the battery or battery bank capacity
    • Battery Charge Temperature Range: 32°F (0°C) to 131°F (55°C)
    • Battery Discharge Temperature Range: -4°F (-20°C) to 140°F (60°C)
    • Cell Charge Temperature: 32°F (0°C) to 131°F (55°C)
    • NOTE: Not all chargers are capable of multistage charging. If yours is not, you will want to verify it can be programmed for the Bulk/Absorption voltage and have the other items mentioned disabled if applicable. Consult your charger's manual or the manufacturer.